Withdrawal and injection at mixed sites explained
Withdrawal and injection explained for mixed sites combining consumption, solar panels and a battery
A consuming site equipped with solar panels and a battery does not just consume or produce: in reality, it withdraws or it injects.
The difference matters: what the power grid sees is neither the site’s gross consumption nor the panels’ gross generation, but the net flow measured at the electricity meter.
- When the site withdraws, electricity flows from the grid to the site.
- When the site injects, electricity flows from the site to the grid.
At any given moment, this net flow depends on four elements:
consumption + battery charging − battery discharging − solar generation
- If the result is positive, the site is withdrawing.
- If it is negative, the site is injecting.
For example, if a site consumes 5 kW, its battery charges at 3 kW and its panels produce 6 kW, the meter will see a net withdrawal of 2 kW.
It is this net power, whether withdrawn or injected, that must be controlled and monetised on flexibility mechanisms.
The virtual power plant (VPP) we are building at Nexen controls behind-the-meter batteries while taking account of the site’s physical reality, its economic logic and the regulatory constraints needed to turn this flexibility potential into revenue.